product manual:

Electro-hydraulic servo system selection guide:

 

1, servo oil pump recommended

The oil pump is selected according to the displacement, flow rate and maximum speed of the pump and motor required by the hydraulic system.

Hydraulic presses, die casting machines Common oil pumps are compared as follows (different brands of oil pumps will be different):

 

 

Piston pumpVane pump

Oil pump type

Volumetric efficiency

Flow pulsation

Rotating speed

Recommended speed(rpm):

noise

Internal gear pump

low

       in

in

2000~2600

  in

high

high

low

1500~2200

high


in

low

high

2000~3200

low


 

2, servo motor selection


Select the torque of the servo motor based on the pump displacement and system pressure.


(1) Calculate the maximum torque of the motor according to the hydraulic principle:


Tmax=0.0159×P×q(Nm)


P: maximum pressure (kgf/cm2), q: oil pump displacement (cc/r)


(2) Determine the rated torque of the motor:


According to engineering experience, the overload capacity of the motor is 1.3 to 1.8 times. When the working condition period is short and the frequency is higher, the overload capacity is 1.3 times. The rated torque of the motor is:


Tm=Tmax/1.3~1.8


(3) Calculation example:


Assuming the oil pump is 50cc/r and the maximum pressure is 175kgf/cm2, the rated torque of the motor is:


Tm=0.0159×50×175/1.8=77.3(Nm)


 


3, servo drive selection


(1) Determine the rated current of the servo drive:


Ie =Tm/Kt/η


Tm: rated motor torque (Nm), Kt: motor torque constant (Nm/A), η: motor efficiency (%)


(2) Servo drive holding current:


Ib=Ie×1.5


Ie: drive rated current (A)


(3) Calculation example:


Assume that the oil pump displacement is 50cc/r, the system pressure is 175kgf/cm2, Kt is 2.8, and the motor efficiency is 92%.


Tm=0.0159×50×175/1.8=77.3Nm


Ie=77.3/2.8/0.92=30A


Ib=30×1.5=45A


The EM500T035C can be selected with a rated current of 32A, a holding current of 45A and a maximum current of 58A.



Suzhou Wohe Fluid Control System Co., Ltd. TEL:0512-66578402,13338660122 E-mail:panyoupu@163.com  QQ:417168484 ICP13011250号-1